弱電機房工程UPS電池更換及保養方法

來源(yuan): 發布日期: 2020.11.09

弱電機房工程中的UPS電池是非常重要的組成部分,為了保證弱電工程的(de)(de)安全(quan)運行,我們需要定(ding)期更(geng)(geng)換UPS電池(chi),今天本文就為大(da)家(jia)介紹一下弱電機房工(gong)程(cheng)UPS電池(chi)更(geng)(geng)換及(ji)保(bao)養(yang)方法,希(xi)望對大(da)家(jia)有(you)(you)所幫助。另外(wai),考慮(lv)到更(geng)(geng)換UPS后備電池(chi)工(gong)作具有(you)(you)嚴格的(de)(de)技術性、安全(quan)性以(yi)及(ji)相(xiang)關(guan)的(de)(de)標準(zhun)規定(ding),機房一定(ding)要做好相(xiang)關(guan)的(de)(de)安全(quan)保(bao)護措施。

弱電機房工程UPS電池更換及保養方法 具體的實施過程如下:

一、準備工作

接到可對(dui)電池(chi)進(jin)行(xing)更(geng)換工(gong)作的(de)(de)(de)(de)通知后,電池(chi)更(geng)換實施工(gong)程師到現場進(jin)行(xing)準(zhun)(zhun)備工(gong)作:確保(bao)UPS主機(ji)的(de)(de)(de)(de)輸(shu)入(ru)供電、新舊(jiu)蓄電池(chi)的(de)(de)(de)(de)登記檢查、機(ji)房內消防系(xi)統煙霧探頭的(de)(de)(de)(de)密封、準(zhun)(zhun)備二(er)氧(yang)化碳滅火器等相(xiang)關工(gong)作。更(geng)換電池(chi)前對(dui)UPS主機(ji)、舊(jiu)電池(chi)組、電池(chi)監測儀等設備做好(hao)相(xiang)關的(de)(de)(de)(de)登記記錄,特別(bie)是每層電池(chi)的(de)(de)(de)(de)擺放、電池(chi)監測儀的(de)(de)(de)(de)接線(xian),要做好(hao)標記,畫好(hao)聯(lian)接圖。保(bao)證電池(chi)組更(geng)換后的(de)(de)(de)(de)效(xiao)果和原(yuan)有(you)的(de)(de)(de)(de)情況保(bao)持一(yi)致;

二、進行電池更換處理

一(yi)切準備就緒后,對電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)進(jin)行(xing)更(geng)(geng)換(huan)處理工(gong)作(zuo)(zuo),斷開UPS主(zhu)機和電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)組(zu)之間(jian)的(de)(de)(de)(de)連(lian)接開關,使(shi)UPS主(zhu)機和電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)組(zu)斷開聯接,確保更(geng)(geng)換(huan)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)時(shi)工(gong)作(zuo)(zuo)人員的(de)(de)(de)(de)安(an)全。對原有電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)組(zu)的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)進(jin)行(xing)拆卸,電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)更(geng)(geng)換(huan)實施(shi)工(gong)程師負責電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)拆卸工(gong)作(zuo)(zuo),相(xiang)關輔助技術人員進(jin)行(xing)新(xin)舊(jiu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)的(de)(de)(de)(de)搬(ban)運工(gong)作(zuo)(zuo)。在(zai)(zai)拆舊(jiu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)時(shi),將(jiang)拆卸下來的(de)(de)(de)(de)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)連(lian)接線和電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)端子的(de)(de)(de)(de)螺(luo)絲(si)用盒子整(zheng)齊的(de)(de)(de)(de)擺(bai)(bai)放(fang)好,保證(zheng)機房(fang)內的(de)(de)(de)(de)整(zheng)潔和清潔。舊(jiu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)拆完后,將(jiang)舊(jiu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)和舊(jiu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)架(jia)整(zheng)齊的(de)(de)(de)(de)擺(bai)(bai)放(fang)在(zai)(zai)甲(jia)方規定(ding)(ding)的(de)(de)(de)(de)位(wei)置。將(jiang)新(xin)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)架(jia)組(zu)裝件安(an)放(fang)在(zai)(zai)制定(ding)(ding)位(wei)置,同時(shi)開始安(an)裝新(xin)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi),將(jiang)新(xin)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)擺(bai)(bai)放(fang)在(zai)(zai)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)架(jia)上,使(shi)新(xin)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)在(zai)(zai)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)架(jia)上的(de)(de)(de)(de)擺(bai)(bai)放(fang)位(wei)置、方向調整(zheng)的(de)(de)(de)(de)最(zui)好。在(zai)(zai)連(lian)接好一(yi)組(zu)電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)后檢(jian)(jian)查電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)端子的(de)(de)(de)(de)連(lian)接線是(shi)否牢固(gu);檢(jian)(jian)查電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)組(zu)的(de)(de)(de)(de)總(zong)電(dian)(dian)(dian)(dian)(dian)(dian)壓是(shi)否正常等(deng)情況,電(dian)(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)(chi)(chi)的(de)(de)(de)(de)正負極要連(lian)接正確;

弱電機房工程UPS電池更換及保養方法——欣榮泰工人施工現場

三、檢查總電壓情況

更(geng)換電(dian)(dian)(dian)(dian)池(chi)工(gong)作完畢后,用(yong)萬用(yong)表檢(jian)查電(dian)(dian)(dian)(dian)池(chi)組的總(zong)電(dian)(dian)(dian)(dian)壓(ya)情況、電(dian)(dian)(dian)(dian)池(chi)組的正負(fu)極(ji)和(he)中(zhong)性(xing)線的接線情況。確(que)保(bao)電(dian)(dian)(dian)(dian)池(chi)組和(he)UPS主機都正常(chang)后,合閉(bi)電(dian)(dian)(dian)(dian)池(chi)組的開關,使UPS不(bu)間斷電(dian)(dian)(dian)(dian)源系統恢復正常(chang)工(gong)作。然后檢(jian)測UPS的工(gong)作電(dian)(dian)(dian)(dian)壓(ya)、電(dian)(dian)(dian)(dian)流、充電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)壓(ya)、工(gong)作狀(zhuang)態等情況并做好記錄。由一(yi)人觀察(cha)主機液晶顯(xian)示(shi)屏里面的參數和(he)實(shi)際(ji)的是否(fou)一(yi)致(zhi),電(dian)(dian)(dian)(dian)池(chi)時間參數進行調試設置(zhi),確(que)保(bao)電(dian)(dian)(dian)(dian)池(chi)在正常(chang)的壽命期間不(bu)會出現錯誤的報警(jing)提示(shi)。UPS主機調試正常(chang)后,斷開UPS主機的輸入電(dian)(dian)(dian)(dian)源開關,模擬市(shi)電(dian)(dian)(dian)(dian)故障中(zhong)斷,測試UPS系統是否(fou)能(neng)正常(chang)由市(shi)電(dian)(dian)(dian)(dian)轉為電(dian)(dian)(dian)(dian)池(chi)組后備電(dian)(dian)(dian)(dian)源供(gong)電(dian)(dian)(dian)(dian),確(que)保(bao)機房機柜內的設備正常(chang)運行;

四、清潔UPS機房

在電(dian)(dian)池更換工(gong)作完成之(zhi)后,對UPS房(fang)(fang)進行(xing)打掃(sao)清(qing)(qing)潔,清(qing)(qing)理雜物,保證UPS房(fang)(fang)的良好環(huan)境。恢復電(dian)(dian)池更換之(zhi)前,機房(fang)(fang)內所(suo)做(zuo)的準備(bei)工(gong)作。而(er)且(qie)應使新電(dian)(dian)池組充電(dian)(dian)至24小時左右(you),確保新電(dian)(dian)池充滿電(dian)(dian)量。

弱電機房工程UPS電池更換及保養方法——欣榮泰施工現場

以上內容為大家科普了弱電機房工程UPS電池更換及保養方法,相信大家已經多多少少了解弱電機房工程UPS電池更換及保養方法了。但如果您在弱電機房中遇到問題的時候,可以咨詢成都欣榮泰實業有限公司。本公司工程師一對一咨詢,為不同應用場景提供機房消防工程、機房 弱電工程機房綜合布線工程公共廣播系統安(an)裝、弱電安(an)裝工程等。

咨詢熱線